IOy Edge I/O Module
BL197 IOy EtherCAT I/O Module
Item No.: BL197
EtherCAT Ethernet IO Module
Introduction
Features
Specifications
Download
Applications
BL197 EtherCAT Combined IO provides 26 I/O board options, including digital input/output, analog input/output, thermocouple and resistance temperature detection, etc., which can be combined into more than 10,000 models to meet a variety of application scenarios, and you can select the I/O modules by physical interfaces, protocols, and I/O functions.
The EtherCAT Ethernet IO Module passing 12 EMC/EMI tests ensures reliability under strong electromagnetic interference.
Ordering Guides
Users can select 1-3 Y series IO boards according to their needs, such as BL197 with 3 Y11 (8DI) can be composed of 24DI EtherCAT IO module, and also supports mix and match such as BL197 with Y11 (8DI), Y31 (4AI), Y52 (2PT) can be combined into 8DI + 4AI + 2PT EtherCAT IO Module.
Naming Rules
IOy-Y
IOy-Y-Y
IOy-Y-Y-Y
Example

Optional Protocols
Optional I/O Boards
The EtherCAT Ethernet IO Module passing 12 EMC/EMI tests ensures reliability under strong electromagnetic interference.
Ordering Guides
Users can select 1-3 Y series IO boards according to their needs, such as BL197 with 3 Y11 (8DI) can be composed of 24DI EtherCAT IO module, and also supports mix and match such as BL197 with Y11 (8DI), Y31 (4AI), Y52 (2PT) can be combined into 8DI + 4AI + 2PT EtherCAT IO Module.
Naming Rules
IOy-Y
IOy-Y-Y
IOy-Y-Y-Y
Example
BL197-Y11 | EtherCAT Protocol 8DI I/O Module |
BL197-Y11-Y11 | EtherCAT Protocol 16DI I/O Module |
BL197-Y11-Y11-Y11 | EtherCAT Protocol 24DI I/O Module |
BL197-Y11-Y21-Y31 | EtherCAT Protocol 8DI+8DO+4AI I/O Module |

Optional Protocols
BL190 | Modbus TCP |
BL191 | OPC UA |
BL192 | MQTT |
BL192Pro | Modbus TCP, OPC UA, MQTT |
BL193 | SNMP |
BL196 | PROFINET |
BL197 | EtherCAT |
BL198 | Ethernet/IP |
BA190 | BACnet/IP |
BA190Pro | BACnet/IP, MQTT, Modbus TCP, OPC UA |
BE190 | IEC104 |
BE190Pro | IEC104, MQTT, Modbus TCP, OPC UA |
Optional I/O Boards
IO Item no. | Function | Description |
Y11 | 8DI NPN | NPN(Low-Level Triggering) |
Y12 | 8DI PNP | PNP(High-Level Triggering) |
Y13 | 8DI | Dry Contact |
Y21 | 8DO PNP | High-level output is active, output 24V DC |
Y22 | 8DO NPN | Low-level output is active, output 0V DC |
Y24 | 4DO Relay | Max voltage: 250VAC/30VDC; Max current: 2A |
Y01 | 4DI+4DO NPN | DI wet or dry contact, DO NPN |
Y02 | 4DI+4DO PNP | DI wet or dry contact, DO PNP |
Y31 | 4AI 0/4-20mA | 0~20mA, 4~20mA analog input, resolution: 16 Bit |
Y33 | 4AI 0-5/10V Single-Ended | 0~5V, 0~10V analog input, resolution: 16 Bit |
Y34 | 4AI 0-5/10V Differential | 0~5V, 0~10V analog input, resolution: 16 Bit |
Y36 | 4AI ±5V/±10V Differential | -5~5V, -10~10V analog input, resolution: 16 Bit |
Y37 | 4CH IEPE Measurement | Low-Impedance Voltage Signal Output |
Y41 | 4AO 0/4-20mA | 0~20mA, 4~20mA analog output, resolution: 12 Bit |
Y43 | 4AO 0-5/10V | 0~5V, 0~10V analog output, resolution: 12 Bit |
Y46 | 4AO ±5V/±10V | -5~5V, -10~10V analog output, resolution: 12 Bit |
Y51 | 2RTD 3-Wire PT100 | 3-wire PT100 |
Y52 | 2RTD 3-Wire PT1000 | 3-wire PT1000 |
Y53 | 2RTD 4-Wire PT100 | 4-wire PT100 |
Y54 | 2RTD 4-Wire PT1000 | 4-wire PT1000 |
Y58 | 4TC | B/E/J/K/N/R/S/T Thermocouple |
Y95 | 8Pulse Output and Pulse Counting | 4CH Pulse Output + 4CH Pulse Counting (NPN) |
Y96 | 8Pulse Output and Pulse Counting | 4CH Pulse Output + 4CH Pulse Counting (PNP) |
Y61 | 4RS485/RS232 | 4*RS485/RS232 optional |
Y62 | 1CAN+3RS485/RS232 | 1*CAN+3*RS485/RS232 reserve |
Description
BL197 EtherCAT Combined IO provides 26 I/O board options, including digital input/output, analog input/output, thermocouple and resistance temperature detection, etc., which can be combined into more than 10,000 models to meet a variety of application scenarios, and you can select the I/O modules by physical interfaces, protocols, and I/O functions.
The EtherCAT Ethernet IO Module passing 12 EMC/EMI tests ensures reliability under strong electromagnetic interference.
Ordering Guides
Users can select 1-3 Y series IO boards according to their needs, such as BL197 with 3 Y11 (8DI) can be composed of 24DI EtherCAT IO module, and also supports mix and match such as BL197 with Y11 (8DI), Y31 (4AI), Y52 (2PT) can be combined into 8DI + 4AI + 2PT EtherCAT IO Module.
Naming Rules
IOy-Y
IOy-Y-Y
IOy-Y-Y-Y
Example

Optional Protocols
Optional I/O Boards
The EtherCAT Ethernet IO Module passing 12 EMC/EMI tests ensures reliability under strong electromagnetic interference.
Ordering Guides
Users can select 1-3 Y series IO boards according to their needs, such as BL197 with 3 Y11 (8DI) can be composed of 24DI EtherCAT IO module, and also supports mix and match such as BL197 with Y11 (8DI), Y31 (4AI), Y52 (2PT) can be combined into 8DI + 4AI + 2PT EtherCAT IO Module.
Naming Rules
IOy-Y
IOy-Y-Y
IOy-Y-Y-Y
Example
BL197-Y11 | EtherCAT Protocol 8DI I/O Module |
BL197-Y11-Y11 | EtherCAT Protocol 16DI I/O Module |
BL197-Y11-Y11-Y11 | EtherCAT Protocol 24DI I/O Module |
BL197-Y11-Y21-Y31 | EtherCAT Protocol 8DI+8DO+4AI I/O Module |

Optional Protocols
BL190 | Modbus TCP |
BL191 | OPC UA |
BL192 | MQTT |
BL192Pro | Modbus TCP, OPC UA, MQTT |
BL193 | SNMP |
BL196 | PROFINET |
BL197 | EtherCAT |
BL198 | Ethernet/IP |
BA190 | BACnet/IP |
BA190Pro | BACnet/IP, MQTT, Modbus TCP, OPC UA |
BE190 | IEC104 |
BE190Pro | IEC104, MQTT, Modbus TCP, OPC UA |
Optional I/O Boards
IO Item no. | Function | Description |
Y11 | 8DI NPN | NPN(Low-Level Triggering) |
Y12 | 8DI PNP | PNP(High-Level Triggering) |
Y13 | 8DI | Dry Contact |
Y21 | 8DO PNP | High-level output is active, output 24V DC |
Y22 | 8DO NPN | Low-level output is active, output 0V DC |
Y24 | 4DO Relay | Max voltage: 250VAC/30VDC; Max current: 2A |
Y01 | 4DI+4DO NPN | DI wet or dry contact, DO NPN |
Y02 | 4DI+4DO PNP | DI wet or dry contact, DO PNP |
Y31 | 4AI 0/4-20mA | 0~20mA, 4~20mA analog input, resolution: 16 Bit |
Y33 | 4AI 0-5/10V Single-Ended | 0~5V, 0~10V analog input, resolution: 16 Bit |
Y34 | 4AI 0-5/10V Differential | 0~5V, 0~10V analog input, resolution: 16 Bit |
Y36 | 4AI ±5V/±10V Differential | -5~5V, -10~10V analog input, resolution: 16 Bit |
Y37 | 4CH IEPE Measurement | Low-Impedance Voltage Signal Output |
Y41 | 4AO 0/4-20mA | 0~20mA, 4~20mA analog output, resolution: 12 Bit |
Y43 | 4AO 0-5/10V | 0~5V, 0~10V analog output, resolution: 12 Bit |
Y46 | 4AO ±5V/±10V | -5~5V, -10~10V analog output, resolution: 12 Bit |
Y51 | 2RTD 3-Wire PT100 | 3-wire PT100 |
Y52 | 2RTD 3-Wire PT1000 | 3-wire PT1000 |
Y53 | 2RTD 4-Wire PT100 | 4-wire PT100 |
Y54 | 2RTD 4-Wire PT1000 | 4-wire PT1000 |
Y58 | 4TC | B/E/J/K/N/R/S/T Thermocouple |
Y95 | 8Pulse Output and Pulse Counting | 4CH Pulse Output + 4CH Pulse Counting (NPN) |
Y96 | 8Pulse Output and Pulse Counting | 4CH Pulse Output + 4CH Pulse Counting (PNP) |
Y61 | 4RS485/RS232 | 4*RS485/RS232 optional |
Y62 | 1CAN+3RS485/RS232 | 1*CAN+3*RS485/RS232 reserve |